A portable generator sitting in the driveway does nothing until you connect it to something. How you make that connection is the part that matters most for safety, and it is also where most people get it wrong. There are three safe methods and one method that is dangerous enough that it is illegal in many places. This guide walks through all of them, in plain terms.
The three safe ways to connect
You can power individual appliances with cords, feed your home’s wiring through a proper inlet and transfer switch (or an interlock), or install a permanent standby system. Each one fits a different budget and a different set of loads.
| Method | Typical cost band | Convenience | What it powers | Permit and electrician |
|---|---|---|---|---|
| Extension cords | Roughly $100–$300 | Low — run cords, watch doorways | A few appliances, one at a time or a small set | None, but use heavy cords rated for the load |
| Generator inlet + interlock kit | Roughly $500–$1,500 installed | Medium — one cord to the house | Chosen circuits in your panel, up to the generator’s limit | Usually a permit; electrician installs the inlet and interlock |
| Generator inlet + manual transfer switch | Roughly $600–$2,000 installed | Medium — flip switches to chosen circuits | A fixed set of circuits wired into the switch | Permit and licensed electrician |
| Automatic standby generator | Often $3,000–$10,000+ installed | High — starts on its own | Whole home or most of it | Permit, electrician, often a gas line and a concrete pad |
Those bands are broad on purpose. Prices vary a lot by region, panel type, and how far the inlet is from the panel. The point is the order of magnitude, not a quote.
Why backfeeding is the one thing never to do
Backfeeding means plugging a generator into a regular wall outlet or dryer outlet using a cord with two male ends, sometimes called a suicide cord. It seems clever because the generator’s power flows backward through your home’s wiring and lights up the whole house. It is also the most dangerous shortcut in this entire topic.
When you backfeed, you are energizing the wires that the utility company also feeds. If the power comes back on while your generator is connected, two sources push electricity into the same wires. That can destroy your generator, start a fire, and — most seriously — send electricity down the line to a utility worker who is repairing the outage and expects those wires to be dead. Linemen have been killed this way.
A transfer switch or an interlock solves the problem by design: it forces your home to disconnect from the utility before the generator can feed the panel. That physical separation is the whole point. There is no safe homemade version of it, and no adapter or cord replaces it.
120V and 240V: which outlets do what
A portable generator usually gives you a mix of outlets. The small household-style ones are 120 volts. The round or twist-lock ones may be 120 volts or 240 volts, and the big 240-volt outlets are what let you power a house panel.
| Outlet type | Voltage | Typical rating | What it is for |
|---|---|---|---|
| Household duplex (5-20R) | 120V | 20A | Extension cords to individual appliances |
| Twist-lock L5-30 | 120V | 30A | Heavy 120V loads, some transfer setups |
| Twist-lock L14-30 | 240V | 30A | Feeding a panel inlet; about 7,200W of capacity |
| Large 14-50 | 240V | 50A | Larger generators; about 12,000W of capacity |
The L14-30 is the common connector for a home inlet on mid-size portables. The 14-50 shows up on bigger units. Either way, the inlet on your house has to match the generator’s outlet, and the wire from the inlet to the panel has to be sized for the current. That is electrician work, not a hardware-store guess.
What the inlet box does
A generator inlet is a weatherproof box mounted on an outside wall, wired back to your transfer switch or panel. You run one cord from the generator to the inlet, and the house is fed. It is the clean alternative to dragging four extension cords through a cracked door in the rain.
The inlet is only half the job. It must connect to either a transfer switch or an interlock kit. A transfer switch is a separate panel that lets you choose which circuits get generator power. An interlock is a sliding plate on your main panel that physically prevents the main breaker and the generator breaker from being on at the same time. Both do the same essential thing: they make it impossible to feed the grid.
A worked example: sizing what you want to run
Suppose you want to keep the refrigerator, the furnace blower, the sump pump, some lights, the router, a TV, and phone charging going during a winter outage. Using typical running and starting watts:
| Load | Running watts | Starting watts |
|---|---|---|
| Refrigerator | 700 | 2,200 |
| Furnace blower | 875 | 2,350 |
| Sump pump | 1,050 | 2,150 |
| LED lights | 100 | — |
| Wi-Fi router | 20 | — |
| TV | 120 | — |
| Phone charging | 10 | — |
Add the running watts: 700 + 875 + 1,050 + 100 + 20 + 120 + 10 = 2,875 watts. Keep continuous load at or under 80 percent of the generator’s rating, so divide by 0.8: 2,875 ÷ 0.8 = 3,594 watts. That is the running size you need.
For starting, take the running total and add the biggest single surge above running. The furnace blower adds 2,350 − 875 = 1,475 watts. The refrigerator adds 1,500. The sump pump adds 1,100. The largest is 1,500, so peak = 2,875 + 1,500 = 4,375 watts. A generator rated around 4,000 running watts with at least 4,400 starting watts covers this list. If you plan to add a window AC later, the numbers climb fast — the wattage calculator will total any load list for you.
Choosing between a transfer switch and an interlock
A manual transfer switch is simpler to understand and lets you pick a fixed set of circuits. It suits a homeowner who knows exactly which circuits matter and does not want to think about breaker positions.
An interlock kit is often cheaper to install because it uses your existing panel, and it lets you choose any circuit by flipping breakers, as long as you stay under the generator’s limit. It requires a panel that accepts the kit, which is why an electrician has to look at it.
Either way, the installation is a permit-and-inspection job in most jurisdictions. If a friend offers to wire it up cheap, decline politely. The failure mode is a house fire or a dead lineman.
What about a permanently installed standby?
A standby generator is wired in permanently, runs on natural gas or propane, and starts by itself within seconds of an outage. It is the most convenient option and the most expensive. If you are weighing that against a portable setup, the generator vs power station comparison covers the broader tradeoffs, and our home standby overview goes deeper on the installed route.
For most households that already own a portable generator, an inlet plus interlock or a manual transfer switch is the sweet spot: safe, relatively affordable, and enough to run the essentials.
Quick checklist
- Never connect a generator to a wall outlet, dryer outlet, or any circuit without a transfer switch or interlock.
- Have a licensed electrician install the inlet, the wiring, and the transfer switch or interlock.
- Get the permit and the inspection. Do not skip either.
- Match the inlet and cord to the generator’s outlet type, typically L14-30 or 14-50 for 240V.
- Size the generator to your load: running watts ÷ 0.8, plus the biggest starting surge.
- Keep the generator outside, at least 20 feet from doors, windows, and vents, with the exhaust pointed away.
- Install battery-powered carbon monoxide alarms where people sleep.
- Store fuel safely, away from the house and any ignition source, and never refuel a hot generator.
- Test the setup with a real load before storm season, while you are calm and it is daylight.
Next step
Add up what you actually need to run before you buy anything. The BlackoutWatt calculator totals running and starting watts, applies the 80 percent rule, and tells you roughly what size generator your list requires — so the electrician and the generator both fit your house.